International Code Council Fire-Inspector-II Questions | Fire-Inspector-II Cheap Dumps
P.S. Free 2025 International Code Council Fire-Inspector-II dumps are available on Google Drive shared by Pass4suresVCE: https://drive.google.com/open?id=1KDsSsnqUyxBi9fXV1iE7KQ_q4V1-1bFI
Our Fire-Inspector-II training materials are excellent. The quality is going through official authentication. So your money paid for our Fire-Inspector-II practice engine is absolutely worthwhile. In addition, you are advised to invest on yourselves. After all, no one can be relied on except yourself. And you can rely on our Fire-Inspector-II learning quiz. We can claim that if you study with our Fire-Inspector-II exam questions for 20 to 30 hours, then you are bound to pass the exam for we have high pass rate as 98% to 100%.
Pass4suresVCE has designed International Code Council Fire-Inspector-II pdf dumps format that is easy to use. Anyone can download the International Code Council Fire-Inspector-II pdf questions file and use it from any location or at any time. International Code Council PDF Questions files can be used on laptops, tablets, and smartphones. Moreover, you will get actual International Code Council Fire-Inspector-II Pdf Dumps file.
>> International Code Council Fire-Inspector-II Questions <<
2025 High Pass-Rate International Code Council Fire-Inspector-II Questions
It is apparent that a majority of people who are preparing for the Fire-Inspector-II exam would unavoidably feel nervous as the exam approaching, If you are still worried about the coming exam, since you have clicked into this website, you can just take it easy now, I can assure you that our company will present the antidote for you--our Fire-Inspector-II Learning Materials. Our company has spent more than 10 years on compiling study materials for the exam in this field, and now we are delighted to be here to share our study materials with all of the candidates for the exam in this field.
International Code Council 67 - Fire Inspector II Exam Sample Questions (Q55-Q60):
NEW QUESTION # 55
Paint spray booths must have a clearance of ___ in. from unprotected combustible materials.
Answer: C
Explanation:
Paint Spray Booth Clearance Requirements
According to the International Fire Code (IFC) 2021, Section 2404.3.2, paint spray booths must have a minimum clearance of 18 inches from unprotected combustible materials.
This clearance requirement helps prevent heat transfer, fire spread, and ignition of nearby combustible materials due to the operation of the spray booth.
2. Why 18 Inches is the Correct Answer
Spray booths generate overspray, vapors, and heat, making clearance essential for fire prevention.
The requirement applies to combustible walls, ceilings, and storage materials surrounding the spray booth.
If combustibles are within 18 inches, additional fire protection such as fire-rated barriers or sprinkler protection may be required.
3. Verification of Other Options
Option A (12 inches) - Incorrect, as the IFC mandates a minimum 18-inch clearance.
Option C (24 inches) - Exceeds the standard clearance requirement but is not the official minimum. Incorrect.
Option D (36 inches) - Some jurisdictions may require larger clearances, but IFC mandates 18 inches as the minimum. Incorrect.
Reference Sources:
International Fire Code (IFC) 2021 - Section 2404.3.2 (Paint Spray Booth Clearance Requirements) NFPA 33: Standard for Spray Application Using Flammable or Combustible Materials (Clearance Guidelines) ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: B. 18 inche
NEW QUESTION # 56
A container in a clean-agent extinguishing system must be refilled or replaced when it shows a loss in original weight of more than five percent, or a loss in original pressure of more than ___ percent.
Answer: C
Explanation:
A container in a clean-agent extinguishing system must be refilled or replaced if it experiences a loss of more than 5% of its original weight or a loss in original pressure of more than 3%. This requirement ensures the system maintains sufficient agent concentration for fire suppression.
Reference to Fire Inspector Documentation:
1. NFPA 2001 - Standard on Clean Agent Fire Extinguishing Systems (2022 Edition) NFPA 2001, Section 7.3.2.1 states that a container must be refilled or replaced if the weight loss exceeds 5% or the pressure loss exceeds 3% from the original fill pressure.
These limits are set to maintain system effectiveness and ensure that a clean-agent system can properly discharge in case of a fire.
2. 2021 International Fire Code (IFC) - Chapter 9 (Fire Protection Systems) IFC 904.10 requires that clean-agent systems be maintained per NFPA 2001 to ensure reliability.
Detailed Explanation of Answer Choices:
Option A (Correct): 3% pressure loss is the correct threshold beyond which a container must be replaced or refilled.
Option B (Incorrect): While 5% is correct for weight loss, it is not the correct value for pressure loss.
Option C (Incorrect): A 10% pressure loss is too high and would compromise system performance before reaching the replacement threshold.
Option D (Incorrect): 12% is well beyond the acceptable loss limit and would pose a significant safety risk.
Thus, the correct and verified answer is: A. 3
NEW QUESTION # 57
Extra-high-rack combustible storage is defined in the fire code as any storage on racks of Class I, II, III, or IV commodities which exceed ___ ft. in height, and any storage on racks of high-hazard commodities which exceed ___ ft. in height.
Answer: D
Explanation:
Definition of Extra-High-Rack Combustible Storage
According to International Fire Code (IFC) 2021, Section 3206.6, extra-high-rack combustible storage is defined as:
Class I, II, III, or IV commodities stored on racks exceeding 40 feet in height.
High-hazard commodities stored on racks exceeding 30 feet in height.
2. Understanding Rack Storage Classifications
Class I-IV Commodities: These refer to general, moderate-risk combustible materials such as wood, paper, and plastics.
High-Hazard Commodities: These are materials that have a higher fire risk, such as highly combustible plastics, flammable solids, and products prone to rapid heat release.
3. Verification of Other Options
Option A (20; 30) - Incorrect, as 40 feet is the correct threshold for Class I-IV commodities.
Option B (30; 40) - Incorrect, as 30 feet applies to high-hazard commodities, not Class I-IV commodities.
Option D (50; 40) - Incorrect, as the correct heights are 40 feet and 30 feet, respectively.
Reference Sources:
International Fire Code (IFC) 2021 - Section 3206.6 (Definition of Extra-High-Rack Storage) NFPA 13: Standard for the Installation of Sprinkler Systems (High-Rack Storage Requirements) ICC Fire Inspector II Study Guide (2021)
NEW QUESTION # 58
Smoking is not permitted within ___ ft. of a transfer point for LP-gas while filling operations are in progress.
Answer: B
Explanation:
Smoking Restrictions Near LP-Gas Transfer Points
According to the International Fire Code (IFC) 2021, Section 3807.2, smoking is not permitted within 25 feet of an LP-gas transfer point while filling operations are in progress.
This prevents ignition hazards, as LP-gas is highly flammable and can ignite from cigarettes, matches, or lighters.
2. Why 25 Feet is the Correct Answer
LP-gas vapors are heavier than air and can travel significant distances before igniting.
The 25-foot clearance requirement is set to prevent accidental ignition due to an undetected vapor leak.
3. Verification of Other Options
Option A (10 feet) - Incorrect, as this is the requirement for smaller propane cylinder storage areas, not transfer points.
Option B (15 feet) - Incorrect, as IFC mandates a 25-foot minimum clearance.
Option D (50 feet) - Incorrect, as the IFC requirement is specifically 25 feet, not 50.
Reference Sources:
International Fire Code (IFC) 2021 - Section 3807.2 (Smoking Prohibitions Near LP-Gas Transfer Points) NFPA 58: Liquefied Petroleum Gas Code (Safe Handling and Transfer Requirements) ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: C. 25 feet. #
NEW QUESTION # 59
The clearance requirement from structures for open burning may be reduced to a minimum of ___ ft. from a structure when the burning is conducted in an approved container.
Answer: A
Explanation:
For open burning, fire codes typically require a minimum clearance from structures to prevent fire spread.
However, when burning is conducted in an approved container, the required clearance distance may be reduced to 15 feet.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 307.4 (Open Burning, Recreational Fires, and Portable Outdoor Fireplaces) IFC 307.4 states that the minimum clearance for open burning is 50 feet but may be reduced to 15 feet when conducted in an approved container that prevents fire spread.
2. NFPA 1 - Fire Code (2021 Edition) - Section 10.11 (Open Burning and Recreational Fires) NFPA 1, Section 10.11.5 aligns with the IFC and allows a minimum of 15 feet clearance for contained burning in approved receptacles.
Detailed Explanation of Answer Choices:
Option A (Incorrect): 10 ft. is too close and does not meet the IFC minimum requirement.
Option B (Correct): 15 ft. is the minimum required distance for burning in an approved container according to IFC 307.4.
Option C (Incorrect): 25 ft. is the standard for recreational fires but not for approved containers.
Option D (Incorrect): 50 ft. applies to open burning without a container, not when using an approved container.
Thus, the correct and verified answer is: B. 15 ft.
NEW QUESTION # 60
......
To contribute the long-term of cooperation with our customers, we offer great discount for purchasing our Fire-Inspector-II exam pdf. Comparing to other dumps vendors, the price of our Fire-Inspector-II questions and answers is reasonable for every candidate. You will grasp the overall knowledge points of Fire-Inspector-II Actual Test with our pass guide and the accuracy of our Fire-Inspector-II exam answers will enable you spend less time and effort.
Fire-Inspector-II Cheap Dumps: https://www.pass4suresvce.com/Fire-Inspector-II-pass4sure-vce-dumps.html
International Code Council Fire-Inspector-II Questions To fit oneself with the market need, they will choose to make progress in one specific developing direction, Though there are three different versions of our Fire-Inspector-II practice guide to cater to all needs of our worthy customers: the PDF, Software and APP online, Moreover, the study material provided to you by Pass4suresVCE Fire-Inspector-II Cheap Dumps is the result of serious efforts by adopting the standard methods employed for the preparation of exam material, Besides, we constantly keep the updating of Fire-Inspector-II dumps torrent to ensure the accuracy of questions.
The post-PC era refers to the replacing of traditional desktops Fire-Inspector-II with mobile devices such as tablets and smartphones, Here we enter the body of the `if` only if the call to `lock` succeeds.
Buy Now To Get Free Real International Code Council Fire-Inspector-II Exam Questions Updates
To fit oneself with the market need, they will Latest Fire-Inspector-II Cram Materials choose to make progress in one specific developing direction, Though there are threedifferent versions of our Fire-Inspector-II Practice Guide to cater to all needs of our worthy customers: the PDF, Software and APP online.
Moreover, the study material provided to you by Pass4suresVCE Fire-Inspector-II Questions is the result of serious efforts by adopting the standard methods employed for the preparation of exam material.
Besides, we constantly keep the updating of Fire-Inspector-II dumps torrent to ensure the accuracy of questions, You just need to show us your Fire-Inspector-II failure certification, then after confirmation, we will deal with your case.
2025 Latest Pass4suresVCE Fire-Inspector-II PDF Dumps and Fire-Inspector-II Exam Engine Free Share: https://drive.google.com/open?id=1KDsSsnqUyxBi9fXV1iE7KQ_q4V1-1bFI