Fire-Inspector-II Reliable Dumps Sheet - Exam Fire-Inspector-II Tutorials
Everybody hopes he or she is a successful man or woman no matter in his or her social life or in his or her career. Thus owning an authorized and significant certificate is very important for them because it proves that he or she boosts practical abilities and profound knowledge in some certain area. Passing Fire-Inspector-II Certification can help they be successful and if you are one of them please buy our Fire-Inspector-II guide torrent because they can help you pass the exam easily and successfully.
PassSureExam provides updated and valid International Code Council Fire-Inspector-II Exam Questions because we are aware of the absolute importance of updates, keeping in mind the dynamic International Code Council Fire-Inspector-II Exam Syllabus. We provide you update checks for 365 days after purchase for absolutely no cost.
>> Fire-Inspector-II Reliable Dumps Sheet <<
Exam Fire-Inspector-II Tutorials | Fire-Inspector-II Valid Braindumps Book
The passing rate of our Fire-Inspector-II study materials is the issue the client mostly care about and we can promise to the client that the passing rate of our product is 99% and the hit rate is also high. Our Fire-Inspector-II practice braindumps are selected strictly based on the Real Fire-Inspector-II Exam and refer to the exam papers in the past years. Our expert team devotes a lot of efforts on them and guarantees that each answer and question is useful and valuable.
International Code Council 67 - Fire Inspector II Exam Sample Questions (Q40-Q45):
NEW QUESTION # 40
The use of listed portable unvented oil-burning heating appliances is prohibited in which of the following occupancies?
Answer: C
Explanation:
Restrictions on Portable Unvented Oil-Burning Heaters
According to the International Fire Code (IFC) 2021, Section 603.4, the use of listed portable unvented oil- burning heating appliances is prohibited in certain occupancies where fire and life safety risks are higher.
The prohibited occupancies include:
Group A (Assembly) - Includes theaters, churches, stadiums, etc.
Group E (Educational) - Includes schools, daycares, etc.
Group I (Institutional) - Includes hospitals, nursing homes, jails, etc.
Group R-1, R-2, R-3, R-4 (Residential Occupancies) - Includes hotels, apartments, assisted living, and residential care facilities.
2. Why These Occupancies Are Prohibited
Portable unvented oil-burning heaters pose a significant fire hazard and can produce harmful gases such as carbon monoxide.
In high-occupancy and residential buildings, improper use or malfunction of these heaters could lead to fatal fire or health hazards.
Ventilation concerns in institutional and assembly settings make these heaters particularly dangerous.
3. Verification of Other Options
Option A (Groups A and B occupancies) - Incorrect, as Group B (Business) is not explicitly prohibited from using these heaters.
Option B (Groups B and F occupancies) - Incorrect, as Group F (Factory/Industrial) is not listed under IFC
603.4 as a prohibited occupancy.
Option C (Groups R-3, M, S-1, and S-2 occupancies) - Incorrect, as M (Mercantile) and S (Storage) occupancies are not listed as restricted areas.
Reference Sources:
International Fire Code (IFC) 2021 - Section 603.4 (Portable Unvented Oil-Burning Heating Appliances) NFPA 1: Fire Code (Portable Heater Use Restrictions in Various Occupancies)
NEW QUESTION # 41
All new building construction must have installed an approved water supply for fire protection which provides a minimum of:
Answer: D
Explanation:
All new building construction must have an approved water supply that meets the minimum fire flow requirements necessary for fire protection. The exact fire flow depends on factors such as building size, occupancy type, construction materials, and hazard levels.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 507.1 (Required Water Supply) IFC 507.1 states that an approved water supply capable of providing the required fire flow must be installed in all new construction projects.
The required fire flow varies based on building classification and must be determined by the authority having jurisdiction (AHJ).
2. 2021 IFC - Appendix B (Fire-Flow Requirements for Buildings)
Table B105.1(2) provides fire flow requirements based on construction type and building area.
Fire flow must be calculated according to the ISO (Insurance Services Office) Fire Suppression Rating Schedule.
Detailed Explanation of Answer Choices:
Option A (Correct): The fire flow requirement is determined based on the building and fire protection needs, making this the correct answer.
Option B (Incorrect): A static pressure of 40 psi at each hydrant is not a universal requirement, as fire flow is the primary factor.
Option C (Incorrect): A static pressure of 60 psi is not the fire code's general requirement; fire flow is the priority.
Option D (Incorrect): 250 gallons per minute (GPM) at a fire-access outlet is not an overall fire code requirement for all buildings-it depends on the structure's classification.
Thus, the correct and verified answer is: A. The required fire flow for fire protection.
NEW QUESTION # 42
What fire-resistance rating is required for interior nonbearing wall and partitions in Type IV construction?
Answer: B
Explanation:
The fire-resistance rating requirements for different building elements in Type IV (Heavy Timber) construction are specified in the 2021 International Building Code (IBC), Table 601 - Fire-Resistance Rating Requirements for Building Elements (Hours).
IBC Table 601 - Fire Resistance for Type IV Construction:
Interior nonbearing walls and partitions in Type IV construction require 0 hours of fire resistance.
This is because Type IV construction primarily relies on large, heavy timber elements that provide inherent fire resistance.
Why Other Options Are Incorrect?
B: 1 hour - Incorrect, as nonbearing interior walls in Type IV construction are not required to have a fire- resistance rating.
C: 1-1/2 hours - Not required by code.
D: 2 hours - Only structural elements like exterior walls in some cases may require fire resistance, but nonbearing interior partitions do not.
NEW QUESTION # 43
One or more approved fire extinguishers must be located within __ ft. of hot work locations.
Answer: B
Explanation:
Fire Extinguisher Requirements for Hot Work Locations
According to the International Fire Code (IFC) 2021, Section 3504.2.6, one or more approved fire extinguishers must be located within 30 feet of hot work locations.
Hot work includes welding, cutting, grinding, brazing, or any operation that generates heat, sparks, or flames.
2. Why 30 Feet is the Correct Answer
Hot work presents a high fire risk, and quick access to fire extinguishers is crucial for immediate response.
The 30-foot requirement ensures that extinguishers are readily accessible without obstructing the work area.
3. Verification of Other Options
Option A (20 feet) - Incorrect, as the IFC mandates a 30-foot minimum distance.
Option C (40 feet) - Incorrect, as this exceeds the maximum distance allowed under the fire code.
Option D (50 feet) - Incorrect, as fire extinguishers must be closer to provide effective fire suppression.
Reference Sources:
International Fire Code (IFC) 2021 - Section 3504.2.6 (Fire Extinguishers for Hot Work) NFPA 51B: Standard for Fire Prevention During Welding, Cutting, and Other Hot Work ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: B. 30 feet. #
NEW QUESTION # 44
The maximum travel distance permitted in a one-story, Group F-2 building equipped with automatic sprinklers and automatic smoke and heat roof vents is __ ft.
Answer: C
Explanation:
The maximum travel distance allowed in a one-story Group F-2 (Factory Industrial - Low Hazard) occupancy with automatic sprinklers and automatic smoke and heat vents is regulated by 2021 International Fire Code (IFC) Table 1017.2 - Exit Access Travel Distance.
IFC Table 1017.2 - Maximum Travel Distance:
For a Group F-2 occupancy equipped with an automatic sprinkler system, the maximum allowable exit access travel distance is 400 feet.
However, when automatic smoke and heat vents are installed, the travel distance is limited to 350 feet.
This is because while the sprinklers control fire spread, smoke and heat vents help with smoke control, allowing for extended egress distances but not as much as without them.
Why Other Options Are Incorrect?
A: 250 ft. - Too restrictive; the IFC allows a longer travel distance in this scenario.
B: 300 ft. - Less than the allowed 350 ft.
D: 400 ft. - Only applicable without smoke and heat vents.
NEW QUESTION # 45
......
Our Fire-Inspector-II learning guide allows you to study anytime, anywhere. If you are concerned that your study time cannot be guaranteed, then our Fire-Inspector-II learning guide is your best choice because it allows you to learn from time to time and make full use of all the time available for learning. Our online version of Fire-Inspector-II learning guide does not restrict the use of the device. You can use the computer or you can use the mobile phone. You can choose the device you feel convenient at any time.
Exam Fire-Inspector-II Tutorials: https://www.passsureexam.com/Fire-Inspector-II-pass4sure-exam-dumps.html
So you should fully trust our Fire-Inspector-II exam preparation: 67 - Fire Inspector II Exam and choose our Fire-Inspector-II practice labs as you top choice, Getting the Fire-Inspector-II certification is a guaranteed way to succeed with IT careers, Our experts will check whether there is an update every day, so you needn't worry about the accuracy of Fire-Inspector-II study materials, Customers of PassSureExam Exam Fire-Inspector-II Tutorials will receive updates till 1 year after their purchase.
Remember, the Web started as a way for researchers Fire-Inspector-II to help one another by sharing information, Optimize your web browsing experience, So you should fully trust our Fire-Inspector-II Exam Preparation: 67 - Fire Inspector II Exam and choose our Fire-Inspector-II practice labs as you top choice.
Brilliantly Updated International Code Council Fire-Inspector-II Exam Dumps
Getting the Fire-Inspector-II certification is a guaranteed way to succeed with IT careers, Our experts will check whether there is an update every day, so you needn't worry about the accuracy of Fire-Inspector-II study materials.
Customers of PassSureExam will receive updates till 1 year after their purchase, Exam Fire-Inspector-II Tutorials The various available online sources for exam preparation either provide complex information or deficient of the required knowledge.