All these three NFPA CWBSP exam questions formats contain the real, valid, and error-free Certified Water-Based Systems Professionals (CWBSP) exam practice test questions that are ideal study material for quick NFPA CWBSP Exam Preparation. Just choose the right PrepAwayExam Certified Water-Based Systems Professionals Questions formats and download quickly and start Certified Water-Based Systems Professionals (CWBSP) exam preparation without wasting further time.
NFPA CWBSP Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
Topic 4
100% CWBSP Correct Answers | CWBSP Reliable Test Duration
To provide our users with the Certified Water-Based Systems Professionals (CWBSP) latest questions based on the sections of the actual exam quesions, we regularly update our CWBSP study material. Also, PrepAwayExam provides free updates of NFPA CWBSP Exam Questions for up to 365 days. For customers who don't crack the NFPA CWBSP test after using our product, PrepAwayExam will provides them a refund guarantee according to terms and conditions.
NFPA Certified Water-Based Systems Professionals Sample Questions (Q90-Q95):
NEW QUESTION # 90
What is the maximum distance of the top of the post on a post indicator valve from final grade?
Answer: A
Explanation:
Post Indicator Valves
6.3.1
Where post indicator valves are used, they shall be set so that the top of each post is 32 in. to 40 in. (800 mm to 1.0 m) above the final grade.
NEW QUESTION # 91
What is the hose stream allowance and duration for rolled paper storage protected using ESFR sprinklers?
Answer: D
Explanation:
ESFR (Early Suppression, Fast Response) sprinklers are designed for high-challenge fire hazards like rolled paper storage. The hose stream allowance for such systems is typically higher to account for the potential need for manual firefighting assistance. 500 gpm for 120 minutes provides a substantial water supply for this purpose.
References: Based on NFPA 13's guidelines for storage and ESFR sprinkler systems.
NEW QUESTION # 92
A sprinkler system employing automatic sprinklers that are attached to a piping system that contains air that might or might not be under pressure, with a supplemental detection system installed in the same areas as the sprinklers, is known as a:
Answer: B
Explanation:
A preaction system is a sprinkler system employing automatic sprinklers that are attached to a piping system that contains air that might or might not be under pressure, with a supplemental detection system installed in the same areas as the sprinklers. The operation of the detection system opens a valve that permits water to flow into the piping system and to be discharged from any sprinklers that have operated. Preaction systems are used to protect areas where accidental activation is undesired, such as museums, libraries, or data centers.
References: NFPA 13, 2019 edition, section 3.3.22.1; NFPA 13 Handbook, 2019 edition, page 30; Types of Sprinkler Systems.
NEW QUESTION # 93
Which Occupancy Classification is defined as occupancies or portions of other occupancies where combustibility is low, quantity of combustibles is moderate, stockpiles of combustibles do not exceed 8 ft (2.4 m), and fires with moderate rates of heat release are expected?
Answer: C
Explanation:
Ordinary Hazard Group 1 is defined as occupancies or portions of other occupancies where combustibility is low, quantity of combustibles is moderate, stockpiles of combustibles do not exceed 8 feet, and fires with moderate rates of heat release are expected.
References: NFPA 13 classifies occupancies into hazard categories based on factors such as combustibility, quantity of combustibles, and expected fire behavior, to guide the design and installation of appropriate fire protection systems.
NEW QUESTION # 94
What is the maximum distance an underground main can be installed under the building to the riser location without additional requirements?
Answer: B
Explanation:
NFPA standards allow a certain distance for underground mains to run under a building to the riser without imposing additional requirements. A distance of up to 5 ft is commonly accepted, providing a practical allowance for connecting the underground water supply to the building's sprinkler system while minimizing potential risks.
References: NFPA guidelines for the installation of fire sprinkler systems, including considerations for underground water supply connections.
NEW QUESTION # 95
......
Now we can say that Certified Water-Based Systems Professionals (CWBSP) exam questions are real and top-notch NFPA CWBSP exam questions that you can expect in the upcoming Certified Water-Based Systems Professionals (CWBSP) exam. In this way, you can easily pass the NFPA CWBSP exam with good scores. The countless NFPA CWBSP Exam candidates have passed their dream NFPA CWBSP certification exam and they all got help from real, valid, and updated CWBSP practice questions, You can also trust on PrepAwayExam and start preparation with confidence.