If you are occupied with your work or study and have little time to prepare for your exam, and you should choose us. Since SPI exam bootcamp is high-quality, and you just need to spend about 48 to 72 hours on studying, and you can pass the exam in your first attempt. We are pass guarantee and money back guarantee, and if you fail to pass the exam by using SPI Exam Dumps, we will give you full refund. In order to let you obtain the latest information for SPI exam braibdumps, we offer you free update for one year after purchasinhg, and the update version will be sent to your email automatically.
ARDMS SPI Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
Topic 4
Topic 5
>> SPI Latest Exam Questions <<
Latest SPI Exam Question - SPI Authorized Pdf
We guarantee that you can enjoy the premier certificate learning experience under our help with our SPI prep guide. First of all we have fast delivery after your payment in 5-10 minutes, and we will transfer SPI guide torrent to you online, which mean that you are able to study soon to avoid a waste of time. Besides if you have any trouble coping with some technical and operational problems while using our SPI Exam Torrent, please contact us immediately and our 24 hours online services will spare no effort to help you solve the problem in no time.
ARDMS Sonography Principles and Instrumentation Sample Questions (Q159-Q164):
NEW QUESTION # 159
What is the purpose of applying compression to the received signals?
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
The primary purpose of compression is to reduce the dynamic range of received echoes, making the image more visually interpretable by adjusting contrast without losing diagnostic information.
According to sonography instrumentation reference:
"Compression reduces the dynamic range of the signal amplitudes to fit within the display range of the monitor while preserving important differences in tissue echogenicity." Therefore, the correct answer is D: Reduce the dynamic range.
-
NEW QUESTION # 160
Which adjustment can maintain the same frame rate when the depth is increased?
Answer: D
Explanation:
When the depth of imaging is increased, the time it takes for the ultrasound pulses to travel to and from the deeper structures also increases, which can reduce the frame rate. To maintain the same frame rate, one effective adjustment is to decrease the image width. Narrowing the image width reduces the number of scan lines required to create each frame, allowing the system to maintain a higher frame rate despite the increased depth.
ARDMS Sonography Principles and Instrumentation guidelines
Kremkau, F. W. (2015). Diagnostic Ultrasound: Principles and Instruments.
NEW QUESTION # 161
Which situation can cause color Doppler noise to overwrite an anechoic or hypoechoic area?
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
When color Doppler gain is set too high, the system amplifies noise signals, leading to random color speckles appearing within anechoic or hypoechoic areas where no true flow exists. This artifact is known as "color bleeding" or "color noise." According to sonography instrumentation reference:
"Excessive color Doppler gain can cause noise to overwrite areas without flow, resulting in false color signals within fluid-filled or hypoechoic structures." Therefore, the correct answer is D: Color gain set too high.
NEW QUESTION # 162
Which outcome is an advantage of more pulses in an ensemble length?
Answer: B
Explanation:
Ensemble length, also known as packet size or Doppler packet, refers to the number of pulses used to calculate each Doppler measurement. Increasing the number of pulses in an ensemble length improves the accuracy of velocity measurements by providing more data points for the Doppler shift analysis. This leads to better estimation of mean velocities and reduces the variability of the measurements, although it may slightly decrease temporal resolution due to the longer time required to acquire the data.
ARDMS Sonography Principles and Instrumentation guidelines
Edelman, S. K. (2017). Understanding Ultrasound Physics.
NEW QUESTION # 163
Which action would increase the frame rate?
Answer: A
Explanation:
The frame rate in ultrasound imaging is influenced by several factors, including the number of focal zones. Each focal zone requires additional transmission and reception cycles, thus decreasing the frame rate. By decreasing the number of focal zones, the system requires fewer cycles per frame, which increases the frame rate. This enhances the temporal resolution, making it easier to capture fast-moving structures in real-time imaging.
Reference:
ARDMS Sonography Principles & Instrumentation Guidelines
Hagen-Ansert SL. Textbook of Diagnostic Ultrasonography. 8th ed. St. Louis, MO: Mosby; 2017.
NEW QUESTION # 164
......
To some extent, to pass the SPI exam means that you can get a good job. The SPI exam materials you master will be applied to your job. The possibility to enter in big and famous companies is also raised because they need outstanding talents to serve for them. Our SPI Test Prep is compiled elaborately and will help the client get the SPI certification. To get a better and full understanding of our SPI quiz torrent, you can just free download the demo of our SPI exam questions.
Latest SPI Exam Question: https://www.free4torrent.com/SPI-braindumps-torrent.html
What's more, part of that Free4Torrent SPI dumps now are free: https://drive.google.com/open?id=1b-88_dsGLQrBsRCpq9gSFModNwsbIspb